Methodology
How the calculator works
The calculator follows the methodology of Offie’s office space guide. The numbers on this page are exactly the values the calculator uses — the page loads them straight from the calculator’s settings.
Workstations: density bands
In the Budapest market, total leased area per employee is typically 7–10 m² (dense, open-plan), 10–18 m² (average, mixed layout) or 19–30 m² (mostly private offices, e.g. law firms). In the calculator an open-plan desk takes m² net (dense) or m² (standard) — with shared rooms and the add-on factor, the result lands in the bands above.
Private offices
We calculate single-person private offices in three sizes: small m², standard m², executive m² — in line with the guide’s 10–15 / 15–20 / 20–30 m² bands. Private offices are never shared: they stand empty on home-office days but the rent still runs, so the hybrid discount applies to open-plan desks only.
Meeting rooms
The guide’s rule of thumb: a meeting room needs about 5 m² plus 2 m² per seat. That gives the calculator’s room sizes: 4-seat m², 8-seat m², 12–16-seat m². If you don’t specify the rooms exactly, we estimate from team size and meeting intensity — roughly one room per 10 employees in denser offices and per 20 in traditional ones.
Shared rooms
| Room | Calculation |
|---|---|
| Kitchen | m² / desk, min. m² |
| Storage, print | m² / desk, min. m² |
| Reception (optional) | m² |
| Server room (optional) | m² |
| Large canteen (optional) | m² / desk, min. m² |
| Circulation | +% on top of the above |
The circulation allowance is lower than the guide’s 10–30% band because our per-desk figures already include local circulation within the work area — we only add the corridors between zones separately.
Hybrid work: peak, not average
This is the calculator’s addition to the original guide. The office is sized by peak attendance, not the average: if everyone comes in on the same days, you need close to a full desk count — remote work does not reduce space in that case. With attendance spread across the week, the peak day runs about 15% above the average, and we never plan for fewer desks than 60% of headcount.
Growth
The guide recommends a 10–20% growth reserve. The calculator sizes the “recommended” figure for the planned headcount in 2 years and gives a range: “lean” is sized for today’s headcount (without planned growth, 90% of the recommended figure), “comfortable” adds 10% headroom — because moving out too early is the most expensive layout mistake.
Net → lettable (gross)
In Budapest, rent is charged on the gross area: the add-on factor for common areas (KTSZ), typically 5–12% per building, is added to the net usable area. By default we use %; when you pick a specific building, we use its actual factor.
Every value is a planning assumption, not a measurement — your advisor refines the final size on the chosen building’s floor plan. The rent estimate always uses asking rent, not rents achieved in signed deals.
Calculate your own space needs.
Two minutes, and you can negotiate with real numbers.