Methodology

How the calculator works

The calculator follows the methodology of Offie’s office space guide. The numbers on this page are exactly the values the calculator uses — the page loads them straight from the calculator’s settings.

01

Workstations: density bands

In the Budapest market, total leased area per employee is typically 7–10 m² (dense, open-plan), 10–18 m² (average, mixed layout) or 19–30 m² (mostly private offices, e.g. law firms). In the calculator an open-plan desk takes m² net (dense) or m² (standard) — with shared rooms and the add-on factor, the result lands in the bands above.

02

Private offices

We calculate single-person private offices in three sizes: small m², standard m², executive m² — in line with the guide’s 10–15 / 15–20 / 20–30 m² bands. Private offices are never shared: they stand empty on home-office days but the rent still runs, so the hybrid discount applies to open-plan desks only.

03

Meeting rooms

The guide’s rule of thumb: a meeting room needs about 5 m² plus 2 m² per seat. That gives the calculator’s room sizes: 4-seat m², 8-seat m², 12–16-seat m². If you don’t specify the rooms exactly, we estimate from team size and meeting intensity — roughly one room per 10 employees in denser offices and per 20 in traditional ones.

04

Shared rooms

RoomCalculation
Kitchen m² / desk, min. m²
Storage, print m² / desk, min. m²
Reception (optional) m²
Server room (optional) m²
Large canteen (optional) m² / desk, min. m²
Circulation+% on top of the above

The circulation allowance is lower than the guide’s 10–30% band because our per-desk figures already include local circulation within the work area — we only add the corridors between zones separately.

05

Hybrid work: peak, not average

This is the calculator’s addition to the original guide. The office is sized by peak attendance, not the average: if everyone comes in on the same days, you need close to a full desk count — remote work does not reduce space in that case. With attendance spread across the week, the peak day runs about 15% above the average, and we never plan for fewer desks than 60% of headcount.

06

Growth

The guide recommends a 10–20% growth reserve. The calculator sizes the “recommended” figure for the planned headcount in 2 years and gives a range: “lean” is sized for today’s headcount (without planned growth, 90% of the recommended figure), “comfortable” adds 10% headroom — because moving out too early is the most expensive layout mistake.

07

Net → lettable (gross)

In Budapest, rent is charged on the gross area: the add-on factor for common areas (KTSZ), typically 5–12% per building, is added to the net usable area. By default we use %; when you pick a specific building, we use its actual factor.

Example: according to the calculator, a 25-person team working full-time in the office, with a standard layout and average meeting needs, can plan with about 325 m² of lettable area (a 295–360 m² range) — roughly 13 m² per person, within the 10–18 m² average band above.

Every value is a planning assumption, not a measurement — your advisor refines the final size on the chosen building’s floor plan. The rent estimate always uses asking rent, not rents achieved in signed deals.